<LOGO>
FM Transmitter Measurement Report
Created: 2024-09-30 23-32-56
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
100.20 MHz 5/5, 36 dBuV INTER
Pilot RDS Phase Difference
7.2 kHz 2.8 kHz -50 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 0,0 kHz
MIN Hold Max. Samples at Total Samples % above 75,0 kHz
13 kHz 65 kHz 15716 1,2153
Modulation Power
Limit Measuring Tolerance
11,0 dBr 0,2 dBr
MIN AVE MAX % above 11,2 dBr
1,2 dBr 2,45 dBr 3,6 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
" INTER " F201 0 (No PTY) 1 0 1 1 23:32, 30.09.2024
RT
"AFFAIRES SENSIBLES - FRANCE INTER 1ERE RADIO DE FRANCE "
AF EON
92.6, 94.6, 94.9, 99.2, 99.9, 100.2 MHz F222, F202, F206, F203
FM Scope Station: 100.20 MHz, signal: 5/5 (36 dBuV) Max at: 65 kHz MIN: 13 kHz % above 75 kHz: 1,2153 Acquired: 2024/09/30 23:31:53 Total samples: 15716 Equivalent time: 0:13:05 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400
FM Scope MAX: 3,6 dBr MIN: 1,2 dBr AVE: 2,45 dBr % above 11,2 dBr: 0,0 Last value: 1,8 dBr (2024/09/30 23:31:52) Station: 100.20 MHz, signal: 5/5 (36 dBuV) 23:20 23:22 23:24 23:26 23:28 23:30 0 50 100 Dev. MAX [kHz] 0 2 4 Pm [dBr] 0 5 Signal Quality